Name | Type, range | SUBID | Default | Description |
---|---|---|---|---|
runtime | integer 0-100 | 1-2 | 15 | runtime is the open/close time in seconds, is used for jalousie, gate, valve(2 pole); Example: runtime=15 |
hold | integer 0-10000 | 1-2 | 500 | hold is the bridging time in miliseconds, is used for gate and jalousie (by default hold is the same as runtime), lock; Example: hold=3500 |
def | string 'ON' | 1-2 | 'OFF' | Def is the element status is set after restart, is used for lamp, heating, valve(1 pole); Example: def='ON' |
offset | float(+/- 0…39) | 30 | '0' | It is the sensor values offset; Example: offset='-15' |
stop | Char 'R' | 1 | – | (for 2-pole gate and blinds) If it is declared then by Stop command during the motion, the same impulse appears as it was at the beginning of the motion. Pole, an which the stop-impules is formed, is defined by the parameter Stop value. If it is 'r' or 'R' then stop-impulse is produced on the opposite to the start-impulse pole. If any other value is delcared (e.g., 'd' ) then the stop-impulse is on the same pole. If a Runtime passed after the beginning of the motion then the stop-impulse is not formed. Example: stop='r' |
out | char[2] | 98 | 'G-' | Each char is responsible for the type of a particular channel |
• 'L'-Lamp, | ||||
• 'M'-Lamp Inverse, | ||||
• 'J'-Heating NO, | ||||
• 'H'-Heating NC, | ||||
• 'B'-Blinds (2 pole), | ||||
• 'C'-Blinds Inverse (2 pole), | ||||
• 'G'-Gate (2 pole), | ||||
• 'D'-Gate (2 pole) Inverse, | ||||
• 'X'-Gate (1 pole /short press), | ||||
• 'Z'-Gate (1 pole) Inverse, | ||||
• 'V'-Valve (2 pole), | ||||
• 'W'-Valve (2 pole) Inverse, | ||||
• 'R'-Valve (1 pole), | ||||
• 'S'-Valve (1 pole) Inverse, | ||||
• 'K'-Lock (short press), | ||||
• 'N'-Lock (short press) Inverse, | ||||
• '-'-none | ||||
Example: |
1hw="out='LM'"
|
| in | char[6] | 98 | 'KKKBBB' | Each char is responsible for the type of a particular channel'B'-Button, 'C'-Inverted button, 'D'-Backlit button, 'E'-Inverted backlit button, 'S'-Switch, 'K'-Contact, 'H'-Inverted contact, '-'-none and you can also connect one temperature sensor
1in='+T----'
Example:
1hw"in='KKKBBB'"
|
<item addr="508:1" cfgid="52" name="Valve" type="valve" uniq_id="4169"/>
<item addr="508:14" cfgid="52" name="Door" type="door-sensor" uniq_id="4168"/>
<item addr="508:15" cfgid="52" name="Switch" type="switch" uniq_id="4128"/>
<item addr="508:30" cfgid="52" name="Temperature" hw="offset='-10'" type="temperature-sensor" uniq_id="4171"/>
<item addr="508:97" cfgid="52" name="Temperature" system="yes" type="temperature-sensor" uniq_id="3998"/>
<item addr="508:98" cfgid="52" hw="out='V-' in='+T-KD-'" name="Temperature" system="yes" type="temperature-sensor" uniq_id="3999"/>