Name Type, range SUBID Default Description
cfg string 98 9600/8N1 cfg='SPEED/BPS', where
• SPEED – baud rate [1200..115200];
• B – data length [7,8];
• P – presence and type of parity bit [N(No parity),E(Even parity),O(Odd parity)];
• S – stop bit length [1, 1.5 or 2].
Example:

hw="cfg='9600/8N1'" | | [Protocol] | string | 98 | — | Protocol setting is described by protocol parameter. The following protocols are supported: • 'modbus', Modbus protocol, at the end of redirection the checksum CRC16(Modbus) is added; • 'dmx', DMX protocol; • 'CO2' for connecting Larnitech CO2 sensors; • 'salda' for connecting Salda ventilation. Example:

hw="cfg='9600/8N1' modbus" | | echo | on; off | 98 | 'off' | For settings check out and testing echo parameter can be used. Moduleecho-reply can be turned on or off with the help of this parameter. Echo parameter value: • 'off' • 'on' Example:

hw="cfg='9600/8N1' echo='off'" |